Search results for "Cooling load"
showing 8 items of 8 documents
Performance maps for an air-cooled air conditioning system as a preliminary instrument for the diagnosis of evaporator fouling
2019
Abstract During the past few decades, there has been increased interest in the development of automated approaches for detecting and diagnosing faults in air conditioning systems. Among them, thermoeconomic diagnosis is a technique which involves the use of exergy analysis. As a first step towards improving its performance, this work is focused on the thermodynamic and exergy analysis of a direct expansion air conditioning system used in small commercial building applications. The analysis was carried out by means of experimental activities on a 17.5 kW rooftop unit installed at the Herrick Laboratories, Purdue University, Indiana (USA). The system under investigation was equipped with a va…
A measurement methodology for monitoring a CHCP pilot plant for an office building
2003
Abstract In Mediterranean areas, climate conditions determine quite equal demand both for thermal and cooling energy. The possibility to convert a cooling demand in thermal one through an absorption chiller allows to extend widely the number of running hours of a cogeneration plant. A trigeneration pilot plant for two office building is described, in which an integrated lay-out includes a NG prime mover with heat exchanger, an absorption chiller and a reversible heat pump. The pilot plant is completed and pre-running test were performed. Different fluid dynamics parameters will be monitored, in order to build the actual cumulative curve for thermal power. The measurement methodology is also…
Potential of Natural Ventilation and Vegetation for Achieving Low-Energy Tall Buildings in Tropical Climate: An Overview
2019
Climate change and rise in urban temperatures have further increased the cooling load demands for tall buildings located in hot climatic regions. Cooling loads in tall buildings can be reduced by integrating them with natural ventilation (NV) and building integrated vegetation (BIV) techniques. This study explores the potential of NV and BIV for obtaining low-energy buildings by analyzing ten tall buildings as case studies. Buildings are analyzed for NV, BIV, architecture design parameters, and energy savings. The results show that mixed-mode ventilation is the most commonly employed, and circular building plans have the highest potential for energy savings. Furthermore, the combination of …
Characterization of cooling loads in the wine industry and novel seasonal indicator for reliable assessment of energy saving through retrofit of chil…
2020
Abstract The food sector is a major consumer of energy and growing efforts are being made in the search for solutions that will guarantee the efficient and sustainable use of energy resources. Among the different sectors, wineries are attracting particular interest due to the continuous growth of the global market and production. Surveys conducted in the winemaking sector have highlighted the importance of performing accurate energy audits and have identified the installation of efficient refrigeration systems as a promising solution in a variety of cases. Unfortunately, the savings achievable by efficient cooling technologies are often estimated using simplified approaches which do not tak…
A Validation Methodology for a Combined Heating Cooling and Power (CHCP) Pilot Plant
2004
A great number of variables significantly influence the energetic, environmental and economic results of CHP (Combined Heating and Power) and CHCP (Combined Heating Cooling and Power) plants operation, and as a consequence their project activity is rather complex. In order to select the best layout and properly size the machines, detailed data on hourly electric, thermal, and cooling demand are necessary, so that a series of plant life cycle simulations may have to be carried out. Unfortunately, such detailed data are rarely available, because energy consumptions data for existing buildings are usually derived from aggregated monthly or bimonthly gas and electricity bills. Even more difficu…
Modelling of Compressors in an Industrial CO $$_2$$ -Based Operational Cooling System Using ANN for Energy Management Purposes
2019
Large scale cooling installations usually have high energy consumption and fluctuating power demands. There are several ways to control energy consumption and power requirements through intelligent energy and power management, such as utilizing excess heat, thermal energy storage and local renewable energy sources. Intelligent energy and power management in an operational setting is only possible if the time-varying performance of the individual components of the energy system is known. This paper presents an approach to model the compressors in an industrial, operational two-stage cooling system, with CO\(_2\) as the working fluid, located in an advanced food distribution warehouse in Norw…
Fifty Years of PMV Model: Reliability, Implementation and Design of Software for Its Calculation
2019
In most countries, PMV is the reference index for the assessment of thermal comfort conditions in mechanically conditioned environments. It is also the basis to settle input values of the operative temperature for heating and cooling load calculations, sizing of equipment, and energy calculations according to EN 16798-1 and 16798-2 Standards. Over the years, great effort has been spent to study the reliability of PMV, whereas few investigations were addressed to its calculation. To study this issue, the most significant apps devoted to its calculation have been compared with a reference software compliant with EN ISO 7730 and the well-known ASHRAE Thermal Comfort Tool. It has been revealed …